A rationale for skew flaps in below-knee amputation surgery. ³


McCollum PT. Spence VA. Walker WF. Murdoch G. Prosthetics & Orthotics International. [JC:ozz] 9(2):95-9, 1985 Aug. The use of thermography in the assessment of amputation levels has demonstrated a medial to lateral thermal gradient in many cases. In order to see whether this reflected a true medial to lateral skin blood flow gradient, a prospective study was set up to measure blood flow medially and laterally below the knee. Twenty-one patients, presenting for amputation assessment with end-stage peripheral vascular disease, were studied. Skin blood flows were measured using an intradermal radioisotope clearance technique. Results showed a highly significant difference between medial and lateral skin blood flows (t = 4.79; p less than 0.001). In view of the significantly higher blood flow in the medial skin of the lower leg, it is suggested that a more medially based posterior below-knee amputation skin flap may be of more value in some patients.



Original Text by Clifford R. Wheeless, III, MD.